Tool is for Joist floor with several Girder options. 1.3C Non-Composite Deck measures 1 5/16-inches in depth; 1.5C Non-Composite Deck measures 1 1/2-inches in depth. It incorporates the benefit of open web configuration along with 48 to 72 joist spacing. HIGH PERFORMANCE DECK-SLAB DIAPHRAGM STRENGTH. 0000009189 00000 n
0000036547 00000 n
Steel used in the production of Vulcraft chord and web sections conform to CSA Specifications. Roof Bay Tool Floor Bay Tool. hb```f``xAb,7 $00 Ix9^{E00iR$ H&p!Kn-6f8gsciXR8!a,$X}Lga`H3]n+V -0_
.Qp L,
endstream
endobj
3055 0 obj
<>
endobj
3056 0 obj
<. 0000012833 00000 n
0000076882 00000 n
0000010964 00000 n
Second to none in service and backed by the Nucor family of quality companies, Vulcraft is destined to be North Americas best one-source for standard, heavy duty, and custom fabricated grating. Columns Calculate your unfilled deck diaphragm shear and stiffness for your exact condition based on the American Iron and Steel Institute AISI S310-16. The tools can be utilized for wide flange and HSS columns. Our online tools will help you select the most cost-effective products for your project, including joists, roof deck, floor deck, composite deck, and dovetail deck. Find 500,000+ High-Quality CAD Drawings to Use in Your Projects for Free CAD DOWNLOAD SAMPLE CAD COLLECTION Browse and download thousands of CAD Drawing files Content Filters MasterFormat Product Type Categories Loading. 0000077244 00000 n
Calculate your deck-slab diaphragm strength and stiffness for selected deck profiles based on AISI S310-16. Vulcraft employs the latest technology in manufacturing and fabricating in its quest to provide quality products on time and to exact specifications. Second to none in service and backed by the Nucor family of quality companies, Vulcraft is destined to be North Americas best one-source for standard, heavy duty, and custom fabricated grating. All rights reserved. By downloading and using any ARCAT content you agree to the following [ license agreement ]. The sheets are intended to augment a Javelin or Estima software layout, or one that is produced by some other means (e.g. Each catalog can be viewed online, downloaded, or ordered. 0000013982 00000 n
The PunchLok II System uses a specially designed pneumatic tool to achieve a stronger and more positive attachment than screwed sidelaps or conventional button punches. Vulcraft provides a number of resources to help you efficiently and successfully specify steel joists and deck. Vulcraft employs the latest technology in manufacturing and fabricating in its quest to . These make it easier to specify Trus Joist products in the software of your choice. Versa-Dek Deep-Dek 1.0 Deck; F Deck; B Deck; NW32 and N Deck; Curve-Dek Architectural Deck. Please limit usage to 6 design tools at a given time for maximum performance. Vulcraft's Dovetail Roof Deck, acoustical and non-acoustical, are IAPMO UES ER-423, UL and/or FM listed. Boxes. The wide ribs make the profile an ideal structural substrate to uniformly support roofing systems applied on top of the deck. Acoustical version of this deck (1.5BA, 1.5BIA and 1.5PLBA) are available. United States:TJ-4015, Spanish:TJ-4015S Black & White:TJ-4015-BW, United States:TJ-4014 Black & White:TJ-4014-BW. 0000318002 00000 n
0000042357 00000 n
The Vulcraft/Verco Group CAD Details below are complete drawings that can easily be downloaded, customized for your residential or commercial project, and included in your CAD library for future use. We want to you choose Trus Joist products, so Weyerhaeuser provides 3D Elements to help you model the structural frame and CAD details to help you provide quality layouts. Note: We are unable to ship manuals to P.O. High Performance Deck-Slab Diaphragm Strength Calculate diaphragm strengths and stiffness for deck-slabs with plain concrete, Bekaert Dramix steel fibers, WWR or rebar. Deck-Slab Diaphragm Strength 0000001896 00000 n
All Cellular acoustical and non-acoustical roof and floor decks are IAPMO UES ER-652, FM and/or UL Listed. The 3NP profile comes in 24 and 32 widths. Tool provides specification guidance, estimated dead loads, stud quantities, bridging, and maximum sizes for ductwork. 0000054279 00000 n
Vulcraft steel deck products are designed and manufactured to meet the requirements of the current edition of CAN/CSA S-136, the National Building Code of Canada (NBCC) as well as requirements of Canadian Sheet Steel Building Institute (CSSBI) stated in CSSBI 10M & CSSBI 12M. Typically used in non-residential construction, steel joists and joist girders provide an economical system for supporting floors and roofs. h1 04Fx\c=t4miCCC. q 2l`[98#(r20_ua;t1AC!c@h}CVg`b&m
0000073282 00000 n
0000075559 00000 n
For custom design information, visit our Online Design Tools. Vulcraft steel deck products are designed and manufactured in accordance with the exacting specifications of the Steel Deck Institute. 3NP Cellular Deck utilizes the N-Deck profile with 3 deep ribs and a full pan underneath. Copyright VULCRAFT 2023.All rights reserved. View Tools BAY ANALYSIS TOOL Tool provides calculations as well as needed info to specify connection. By using this website, you agree to ourPrivacy Policy. 2VLP and 3VLP Cellular Deck utilizes the 2VLI and 3VLI deck profiles, respectively, with a full pan underneath. Compares the shear and moment diagram for two different loading conditions. Vulcraft manufactures a full range of joists, including standard joists, joist girders, and composite joists, designed to work compositely with the concrete slab that is placed on top of the steel deck, creating a very efficient floor system. The 2VLI and 3VLI profiles are 2-inches deep and 3-inches deep, respectively. Each catalog can be viewed online, downloaded, or ordered. 0000073361 00000 n
1.5F (intermediate rib) and 1.5A (narrow rib) deck are still available from Vulcraft. Versa-Dek Deep-Dek Curve-Dek Composite Deck. By downloading and using any ARCAT CAD content you agree to the following [ license agreement] 0000077683 00000 n
deck type gauge c p t b p t b c t p c p b 24 22 20 19 18 16 p t c b roof indiana nebraska south carolina texas alabama/new york approximate dimensions in inches 1.5b, 1.5bl, 1.5ba, 1.5bia . Thousands of free, manufacturer specific CAD Drawings, Blocks and Details for download in multiple 2D and 3D formats organized by MasterFormat. 0.6C Non-Composite Deck measures 9/16-inches in depth and is available in a variety of finishes. These profiles are also available with acoustical properties (1.5VLPA,1.5PLVLPA, 2.0VLPA, 2.0PLVLPA, 3.0VLPA and 3.0PLVLPA). These details are compatible with AutoCAD 2000 and newer. This panel is used in long span conditions ranging from six feet to sixteen feet in distance. 0000068587 00000 n
Vulcrafts Non-Composite Deck is used as a foundation for floors, stairways, or mezzanines. These cover sheets address typical framing details for residential construction and may require modification by design professional for multi-family or commercial projects. For best output results, we recommend the following: Individual Details North America (English), Individual Details North America (Spanish). 0000002600 00000 n
0000074161 00000 n
Copyright VULCRAFT 2023.All rights reserved. Vulcraft/Verco Group Metal Decking CAD Details The Vulcraft/Verco Group CAD Details below are complete drawings that can easily be downloaded, customized for your residential or commercial project, and included in your CAD library for future use. Stock products can be supplied quickly from strategically located sales and warehouse facilities. They should always be used in conjunction with the Specifications and Code of Standard Practice sections of the 43rd Edition. We're working together to be the worlds premier timber, land, and forest products company. Download Tables, These Metric Load Tables are based on the Steel Joist Institute 43rd Edition Specifications and are provided as an easily accessible tool. 0000011612 00000 n
Vulcraft welders supplying joists to the Canadian market are certified to Canadian Welding Bureau (CWB)) W47/W59 standards and the plants are certified as Div. The Ecospan Structural Floor System is ideally suited for multistory residential and commercial buildings. ZipFile.zip Access Free CAD, BIM and Specifications Access Thousands of Free CAD Drawings, BIM Models & Product Specifications Your North American Source for High-Quality Building Product Information All All CAD BIM 3D Specs Products Projects Search 0000074599 00000 n
Vulcraft designs and manufactures its steel deck in accordance with the specifications of the Steel Deck Institute. Both squares and rounds are commonly used as bracing members of light structures. We're focused on climate change solutions, creating sustainable homes for everyone, and supporting thriving rural communities. Analyze your joist for combined uniform and concentrated loading. 0000010912 00000 n
Each catalog can be viewed online, downloaded, or ordered. Below are links to download these items for AutoCADand SketchUp. CANADIAN INSTITUTE OF STEEL CONSTRUCTION (CISC/ICCA), CANADIAN SHEET STEEL BUILDING INSTITUTE (CSSBI/ICTAB), AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC). Steel decking is used in many applications but is particularly well suited to roofing and flooring. 0000078565 00000 n
4.9 - Tilt-Up / Pre-Cast Wall 4.10 - Non-Load Bearing Masonry Wall 4.11 - Structural Parapet Details 4.12 - Auxiliary Rafter Details 4.13 - Lean-To Rafter Details 4.14 - Spandrel Beam Details 5.0 - Nucor CFR Standing Seam Roof System 5.5 - Nucor VR16 II Vertical Rib Standing Seam Roof 6.0 - Classic Wall & Roof Sheeting The tools can be utilized for wide flange and HSS columns. Vulcraft Cellular Decking is ideal for exposed ceiling areas where a flat bottom ceiling is desired without compromising load capabilities. Products Steel joists 0
trailer
Building on its long history of success in the steel joist and deck industry, Vulcraft is well positioned to estimate, detail, custom fabricate, and deliver superior steel bar grating in virtually any configuration. Vulcraft provides a number of resources to help you efficiently and successfully specify steel joists and deck. @F 0000045367 00000 n
vulcraft - steel roof and floor deck ref drawn checked notes bundle no length sqr's mrk qty req'd ft in . hbbd```b``6 Ds@$f0&;@@7="H R,f \k$ 6.`Xd.0m6Sl)TV"H68Gm:#w-9@
endstream
endobj
startxref
0
%%EOF
3113 0 obj
<>stream
Please limit usage to 6 design tools at a given time for maximum performance. This allows for maximum design and installation flexibility of HVAC and electrical systems. The Ecospan Structural Floor System provides innovative, results-driven building solutions. These profiles are also available with acoustical properties (2.0DA & 3.5DA). 0000012748 00000 n
0000082314 00000 n
Steel members are designed per the latest edition of CAN/CSA S-16. The deck profile configu- ration can also be used to interlock concrete and steel. Calculate your maximum unshored span for thick slabs based on your design criteria. Vulcraft manufactures a wide variety of steel bar grating including standard, heavy duty and customized shapes and sizes with various finishes making our products suitable for all kinds of applications. Both profiles are available in a variety of finishes. Vulcraft provides a number of roof deck profiles, each one with unique benefits designed to meet the requirements for a wide variety of projects. Dovetail Deck profiles create a highly effective and value-added deck type for roof systems. Vulcraft estimates, details, and custom fabricates steel bar grating in virtually any configuration. As stewards of these assets, we maximize the value of every acre. These decks come in a variety of finish options. 3. It incorporates the benefit of open web configuration along with 48 to 72 joist spacing. 3897 0 obj
<>
endobj
STANDARD SPECIFICATIONS), DESIGNING WITH VULCRAFT STEEL JOISTS, JOIST GIRDERS AND STEEL DECK 3RD EDITION, VULCRAFT BRIDGING GUIDE BASED ON SJI SPECS 45TH EDITION, VULCRAFT DECK SOLUTIONS COMBINED DESIGN DATA SHEETS, VULCRAFT DECK SOLUTIONS LRFD DATA SHEETS SUPPLEMENTAL, VULCRAFT FM DECK REPORTS (UPDATED FOR PUNCHLOK), STEEL VULCRAFT STEEL DECK SOLUTIONS MANUAL. 0000022014 00000 n
VULCRAFT UL FLOOR - 2 | MAY 2021 VULCRAFT COMPOSITE DECK UL FIRE RATED ASSEMBLIES WWW.VULCRAFT.COM UL Fire Resistance Ratings Restrained Assembly Ratings (hr.) 0000064414 00000 n
0000072921 00000 n
0000075480 00000 n
0000076000 00000 n
Founded in 1946, Vulcraft is the largest producer of open web steel joists and joist girders in North America. Vulcraft/Verco Group CAD Details ARCAT Free Architectural CAD drawings, blocks and details for download in dwg and pdf formats for use with AutoCAD and other 2D and 3D design software. GRADE 50 STEEL 1.5B ROOF DECKS 1.5B-36 Deck used with Side-lap Screws 1.5BI-36 Deck used with TSWs or BPs 1.5PLB-36 Deck used with PunchLok II System Nominal Dimensions Section Properties Deck WeightBase Metal ThicknessYield Strength Effective Moment of Inertiaat Service Load = (2I e+Ig)/3d Effective Section Modulus at F = 50 ksi Allowable Moment 0000078124 00000 n
Analyze floor system for Vibration based on Walking criteria using SJI TD5 and AISC DG11. Metals Metal Decking Default Recent 28 CAD Drawings for Category: 05 30 00 - Metal Decking PLW3-36 Formlok is 3" deep and is in stock in galvanized G60. Type B profiles are typically used for span conditions of 10 feet or less. Steel decking is used in many applications but is particularly well suited to roofing and flooring. View Site, These design tools have been developed by the Steel Joist Institute to assist the SER, the Connection Designer, and the Steel Fabricator with the complex task of designing appropriate connections between Joist Girders and columns. 0000059559 00000 n
When inserting the details directly into a PAPERSPACE drawing, use a 1:1 scale factor and then plot using a 1:1 scale. The following details are examples of common joist bearing conditions. Vulcraft manufactures a full range of joists, including standard joists, joist girders, and composite joists, designed to work compositely with the concrete slab that is placed on top of the steel deck, creating a very efficient floor system. 0000003002 00000 n
Building on its long history of success in the steel joist and deck industry, Vulcraft is well positioned to estimate, detail, custom fabricate, and deliver superior steel bar grating in virtually any configuration. N Deck profiles have 3-inch deep ribs making them ideal for span conditions greater than 10 feet or when a specific aesthetic look is desired. This series is based on the Vulcraft open web steel joist manual, and has greatly enhanced the capabilities of this module. hb```f` ( l@Q>0eA1ld800Z pif=f9!~];'9'0`soI3$XoK;Xt8(XgR&u;GBg>njyy^iN]%]4M_3x[ RK_[J~qiRX:NG_p2a2mDF+g }+: ,qqKC4qAtTJJ ii1,b``M 5`BZC `
Bl,
Armatherm Thermal Bridging Solutions The tool provides a number of input options allowing for customization based on project criteria and designer preference as well as owner and code requirements. If you wish to order a hardcopy, check the box next to each catalog you wish to receive (if available), then simply fill out the contact form provided. Fire Sprinkler Details For installation instructions, consult the Fire-Rated Assemblies and Sprinkler Systems Guide. The uniform load being supported generally is not a factor when selecting a non-composite deck because it is only being used to form concrete and not designed to provide positive reinforcement. If you wish to order a hardcopy, check the box next to each catalog you wish to receive (if available), then simply fill out the contact form provided. All Vulcraft joists and joist girders are designed and manufactured to meet the project specifications and drawings, generally in accordance with the current editions of National Building Code of Canada (NBCC) or Provincial Building Codes of Canada, and the requirements of CAN/CSA S-16. Combining functional structural and aesthetic design and affordability in one product, the Vulcraft 1.5BP Structural Cellular Ceiling/Deck is the best of all design options. The details found within the following links can be downloaded to your computer and viewed using AutoCAD. Building Information Modeling (BIM) continues to progress through all phases of construction, including the steel joist industry. We offer a range of exciting career opportunities for smart, talented people who are passionate about making a difference. Vulcraft Literature. Each catalog can be viewed online, downloaded, or ordered. Where a design professional is not involved, use of these cover sheets is limited to residential applications and, except for the title block, content should not be manipulated as it has been approved by Weyerhaeuser engineering for the loads and framing typical in residential applications. Four different shapes are illustrated in Figure 7-5. All rights reserved. Our latest catalogs are listed below. Its excellent acoustical performance with a noise Reduction Coefficient (NRS) of 0.95 to 1.15 can achieve greater clarity of original sound and deliver a calm, quieter interior environment especially in structures such as auditoriums natatoriums, schools, gymnasiums and theaters. Note: We are unable to ship manuals to P.O. All welds conform to CSA W59. Typically used in non-residential construction, steel joists and joist girders provide an economical system for supporting floors and roofs. Bridge-Dek Rhino-Dek Matching Rebar Deck; Accessories; Finishing .
0000079006 00000 n
K-Series: DWG | PDF LH Series: DWG | PDF Joist Girders: DWG | PDF. Pick Up Locations in Ontario, California and Phoenix, Arizona Delivery Is Available Throughout The USA Dimensions download dimensions Product Data Deck Type: Composite Floor Deck Panel Type: W2-36 Formlok Available Gauges: 22, 20, 18, 16 Available Finishes: Galvanized G-60 0000068628 00000 n
0000011192 00000 n
2.0C Non-Composite Deck measures 2-inches in depth; 3.0C Non-Composite Deck measures 3-inches in depth. CAD/BIM CAD / BIM. Steel joists and joist girders are key components of todays roofing and flooring systems. Open web steel joists are an engineered, truss-like construction component used to support loads over short and long spans alike. ARCAT | Free Building Product CAD Drawings, BIM, Specs and more For custom design information, please visit our Online Design Tools. All rights reserved. The CAD files can be edited to create the exact joist details that your project requires. 0000076803 00000 n
0000031231 00000 n
Vulcraft Cellular decks are designed in accordance with the ANSI/Steel Deck Institute RD-2017 and C-2017. Their dimensions, in inches, apply to the side of the square or the diameter of the round. Set the Lineweight of color 30 to .0075 in your Plot Style, Set the Lineweight of color 134 to .0039 in your Plot Style, Set your drawing LTSCALE to 1/4 of your intended plot scale (e.g., LTSCALE=12 when plotting to a 1/4=1 or 48 scale factor).